Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE
Choose a sub category:
BUILDING WIRE / NM BUILDING WIRE / THHN BUILDING WIRE / UF
ENTRANCE CABLE ARMORED CABLE GROUND WIRE
LAMP CORD SJ CORD SPECIALTY WIRE
Sort By:
1
Zenith AS110024C Speaker Wire Zenith AS105016C Speaker Wire Zenith AS105018C Speaker Wire
The Zenith 24 ga Speaker Wire, 100 ft provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. The Zenith 16 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. The Zenith 18 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity.
Zenith AS110018C Speaker Wire WIRE THERM CL-2 18/2 BRN 100FT Romex SIMpull 14/2NM-WGX25 Building Wire
The Zenith 18 ga speaker wire provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. Southwire SIMpull Thermostat Wire, Type CL-2, 18 AWG Wire, 100 ft Length, 2 Conductors, Copper Conductor, Plastic Conductor Insulation, Solid, PVC Sheath, Brown Sheath, 150 V, Moisture, Sunlight Resistance, -20 to 60 deg C Operating Romex Building Wire, NM-B, 14 AWG Wire, 25 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Nylon Sheath, White Sheath, 600 V, 15 A, 90 deg C Operating
Duraclad 55274921 Type MC Armored Cable Duraclad 55278321 Type MC Armored Cable Armorlite 68579221 Type MC Armored Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.
Zenith AS105014C Speaker Wire Romex SIMpull 12/2NM-WGX25 Building Wire Armorlite 68580021 Type MC Armored Cable
The Zenith 14 ga speaker wire, 50 ft provides connection from your speaker to your audio/video receiver or amplifier. This wire features two conductors made of copper that are insulated for undistorted signal. One side of the clear outer PVC jacket is marked with a white stripe to indicate polarity. Romex Building Wire, NM-B, 12 AWG Wire, 25 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Nylon Sheath, Yellow Sheath, 600 V, 20 A, 90 deg C Operating Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.
Southwire 22973236 THHN Building Wire Southwire 22974036 THHN Building Wire Southwire 22975736 THHN Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 22977336 THHN Building Wire Duraclad 55278521 Type MC Armored Cable Duraclad 55275021 Type MC Armored Cable
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Romex SIMpull 14/2NM-WGX50 Building Wire Romex SIMpull 14/2UF-W/GX25 Building Wire Duraclad 55278322 Type MC Armored Cable
Romex Building Wire, NM-B, Wire Size: 14 AWG, 50 ft L, Number of Conductors: 2, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Sheath Material: Nylon, Sheath Color: White, 600 V, 15 A, Operating Temperature: 90 deg C Southwire Feeder Cable with Ground, Underground, 14 AWG Wire, 25 ft Length, 2 Conductors, Copper Conductor, PVC Sheath, Gray Sheath, 600 V, 90 deg C Operating Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Romex SIMpull 14/3NM-WGX25 Building Wire Romex SIMpull 14/2UF-WGX50 Building Wire Romex SIMpull 12/2NM-WGX50 Building Wire
Romex Building Wire, NM-B, THHN, Wire Size: 14 AWG, 25 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Pink, 600 V, 15 A, Operating Temperature: 90 deg C, Includes: Ground Wire Romex Building Wire, UF-B, Wire Size: 14 AWG, 50 ft L, Number of Conductors: 2, Strands per Conductor: 2, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Gray, 600 V, 15 A, Operating Temperature: 90 deg C Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 22964152 THHN Building Wire Armorlite 68579222 Type MC Armored Cable Duraclad 55274922 Type MC Armored Cable
Southwire Building Wire, THHN, Wire Size: 12 AWG, 100 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Romex SIMpull 12/2UF-W/GX25 Building Wire SIMpull 22964151 THHN Building Wire SIMpull 22965851 THHN Building Wire
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Southwire Building Wire, THHN, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F Southwire Building Wire, THHN, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F
SIMpull 22966651 THHN Building Wire SIMpull 22968251 THHN Building Wire Armorlite 68583421 Type MC Armored Cable
Southwire Building Wire, THHN, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Red, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F Southwire Building Wire, THHN, Wire Size: 12 AWG, 50 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Green, Sheath Diameter: 0.13 in, 600 VAC, 20 A, Operating Temperature: 194 deg F Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.
Armolite 68580022 Solid Metal Clad Cable Romex SIMpull 14/3NM-WGX50 Building Wire Romex SIMpull 12/2UF-WGX50 Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Romex Building Wire, NM-B, 14 AWG Wire, 50 ft Length, 3 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 19 mil Sheath Diameter, 600 V, 15 A, 90 deg C Operating, Includes: Ground Wire Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Romex SIMpull 14/2NM-WGX100 Building Wire Romex SIMpull 14/2UF-WGX100 Building Wire Southwire 14YEL-SOLX500 Building Wire
Romex Building Wire, NM-B, THHN, 14 AWG Wire, 100 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 19 mil Sheath Diameter, 600 V, 15 A, 90 deg C Operating, Includes: Ground Wire Southwire? copper UF-B cable is generally used as feeder to outside post lamps, pumps and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 V. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 14BLUE-SOLX500 Solid Single Building Wire Southwire 14BK-SOLX500 Solid Single Building Wire Southwire 14WHT-SOLX500 Solid Single Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Romex Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Black, 600 V, 15 A, Operating Temperature: 90 deg C Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 14RED-SOLX500 Solid Single Building Wire Southwire 14GRN-SOLX500 Solid Single Building Wire Romex SIMpull 12/3NM-WGX25 Building Wire
Romex Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Red, 600 V, 15 A, Operating Temperature: 90 deg C Romex Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Green, 600 V, 15 A, Operating Temperature: 90 deg C Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Southwire 14BLUE-STRX500 Stranded Single Building Wire Southwire 14BK-STRX500 Stranded Single Building Wire Southwire 14WHT-STRX500 Stranded Single Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, Sheath Diameter: 109 mil, 600 V, 15 A, Operating Temperature: 90 deg C Romex Building Wire, THHN, Wire Size: 14 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: White, 600 V, 15 A, Operating Temperature: 90 deg C
Southwire 14RED-STRX500 Stranded Single Building Wire Southwire 14GRN-STRX500 Stranded Single Building Wire Duraclad 55278323 Type MC Armored Cable
Southwire Building Wire, THHN, #14 AWG Wire, 500 ft Length, 1 Conductors, Copper Conductor, PVC Conductor Insulation, Stranded, Nylon Sheath, Red Sheath, 15 mil Sheath Diameter, 600 V, 15 A, 90 deg C Operating Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Southwire 22973237 THHN Building Wire Southwire 22977337 THHN Building Wire Southwire 22974037 THHN Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 22975737 THHN Building Wire Romex SIMpull 10/2NM-WGX25 Building Wire Romex SIMpull 12/2NM-WGX100 Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Romex Building Wire, NM-B, THHN, 12 AWG Wire, 100 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, Yellow Sheath, 600 V, 20 A, 90 deg C Operating
Romex SIMpull 14/2NM-WGX250 Building Wire Romex SIMpull 10/2UF-W/GX25 Type UF-B Building Wire Duraclad 55274923 Type MC Armored Cable
Romex Building Wire, NM-B, THHN, 14 AWG Wire, 250 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 600 V, 15 A, 90 deg C Operating Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Romex SIMpull 12/3UF-WGX50 Type UF-B Building Wire Romex SIMpull 14/3NM-WGX100 Building Wire Romex SIMpull 10/3NM-WGX25 Building Wire
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/3NM-WGX50 Building Wire WIRE BUILDING 8/3NM-B W/G 25FT Southwire 12YEL-STRX500 Stranded Single Building Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 12YEL-SOLX500 Solid Single Building Wire Southwire 12BK-SOLX500 Solid Single Building Wire Southwire 12WHT-SOLX500 Solid Single Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Romex Building Wire, THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: White, 600 V, 20 A, Operating Temperature: 90 deg C
Southwire 12RED-SOLX500 Tungsten Quartz Single Ended Building Wire Southwire 12BLU-SOLX500 Solid Single Building Wire Southwire 12GRN-SOLX500 Solid Single Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Romex Building Wire, THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Green, 600 V, 20 A, Operating Temperature: 90 deg C
Southwire 12WHT-STRX500 Single Ended Building Wire Southwire 12RED-STRX500 Stranded Single Building Wire Southwire 12BLU-STRX500 Stranded Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Romex Building Wire, THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Red, 600 V, 20 A, Operating Temperature: 90 deg C Southwire? SIMpull? THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull? THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 12GRN-STRX500 Stranded Single Building Wire Armolite 68580023 Solid Metal Clad Cable Armolite 68583422 Solid Metal Clad Cable
Romex Building Wire, THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Green, 600 V, 20 A, Operating Temperature: 90 deg C Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.
Romex SIMpull 12/2NM-WGX250 Building Wire Southwire 12BK-STRX500 Stranded Single Building Wire Romex SIMpull 12/3UF-WGX100 Type UF-B Building Wire
Romex Building Wire, NM-B, 12 AWG Wire, 250 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, Yellow Sheath, 600 V, 20 A, 90 deg C Operating Romex Building Wire, THHN, Wire Size: 12 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, 600 V, 20 A, Operating Temperature: 90 deg C Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Romex SIMpull 14/2UF-W/GX250 Building Wire Romex SIMpull 12/2UF-WGX100 Building Wire WIRE BUILDING 6/3NM-B W/G 25FT
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C.
Romex SIMpull 10/2UF-WGX50 Building Wire Romex SIMpull 10/2NM-WGX50 Building Wire Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Romex Sheathed Cable, NM-B, Wire Size: 12 AWG, 100 ft L, Number of Conductors: 3, Strands per Conductor: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Purple, 600 V, 20 A, Operating Temperature: 90 deg C
Romex SIMpull 14/3NM-WGX250 Building Wire Romex SIMpull 10/3NM-WGX50 Building Wire Romex SIMpull 10/3UF-WGX50 Type UF-B Building Wire
Romex Building Wire, NM-B, THHN, 14 AWG Wire, 250 ft Length, 3 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, White Sheath, 19 mil Sheath Diameter, 600 V, 15 A, 90 deg C Operating, Includes: Ground Wire Romex Building Wire, NM-B, 10 AWG Wire, 50 ft Length, 3 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, Orange Sheath, 600 V, 30 A, 90 deg C Operating Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Coleman 600006601 SPT-1 Lamp Cord Coleman 600006608 SPT-1 Lamp Cord Coleman 600006619 SPT-1 Lamp Cord
Southwire Lamp Cord, 18 AWG Wire, 250 ft Length, 2 Conductors, Copper Conductor, Stranded, PVC Sheath, White Sheath Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool.
Coleman 600006607 SPT-1 Lamp Cord Coleman 600006618 SPT-1 Lamp Cord Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool. Romex Building Wire, NM-B, THHN, Wire Size: #10 AWG, 100 ft L, Number of Conductors: 2, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Solid, Sheath Material: Nylon, Sheath Color: Orange, Sheath Diameter: 24 mil, 600 V, 30 A, Operating Temperature: 90 deg C, Includes: Ground Wire
WIRE BUILDING 8/3NM-B W/G 50FT Southwire 10BLU-SOLX500 Solid Single Building Wire Southwire 10BK-SOLX500 Solid Single Building Wire
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 10WHT-SOLX500 Solid Single Building Wire Southwire 10RED-SOLX500 Solid Single Building Wire Southwire 10GRN-SOLX500 Solid Single Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull? THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull? THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 10BK-STRX500 Stranded Single Building Wire Southwire 10WHT-STRX500 Stranded Single Building Wire Southwire 10RED-STRX500 Stranded Single Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Southwire Building Wire, THHN, Wire Size: 10 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: Thermoplastic, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 161 mil, 600 V, 30 A, Operating Temperature: 90 deg C Southwire Building Wire, THHN, #10 AWG Wire, 500 ft Length, 1 Conductors, Copper Conductor, PVC Conductor Insulation, Stranded, Nylon Sheath, Red Sheath, 161 mil Sheath Diameter, 600 V, 30 A, 90 deg C Operating
Southwire 10BLU-STRX500 Stranded Single Building Wire Southwire 10GRN-STRX500 Stranded Single Building Wire Romex SIMpull 14/3UF-WGX250 Type UF-B Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull? THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull? THHN? copper conductors are designed to be installed without application of a pulling lubricant. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Romex SIMpull 10/2UF-WGX100 Type UF-B Building Wire Romex SIMpull 12/2UF-W/GX250 Building Wire Armolite 68583423 Solid Metal Clad Cable
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.
Duraclad 55278301 Type MC Armored Cable Barostat 553056607 Solid Type CL-2 Thermostat Cable Coleman 553046607 Type CL-2 Electrical Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems. Southwire Thermostat Wire, 18 AWG Wire, 250 ft Length, 5 Conductors, Copper Conductor, Polypropylene Conductor Insulation, Solid, PVC Sheath, Brown Sheath, 0.17 in Sheath Diameter, 150 V, 6.32 Ohm Resistance, -20 to 60 deg C Operating CCI Thermostat Cable, 18 AWG Wire, 250 ft Length, 4 Conductors, Copper Conductor, PVC Conductor Insulation, Solid, Brown Sheath, 150 V, 60 deg C Operating
Coleman 94605M418 Type CL-2 Speaker Cable WIRE BUILDING 6/3NM-B W/G 50FT Romex SIMpull 10/3UF-W/GX100 Type UF-B Building Wire
Parallel wire, power limited circuit cable, -20 to 105 deg C. Used for stereos and hi-fi systems, home theater sound systems, lamps and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. 250 ft per roll. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Armorlite 68580001 Type MC Armored Cable Coleman 601266607 SPT-2 Lamp Cord Coleman 601266608 SPT-2 Lamp Cord
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool.
Coleman 601266601 SPT-2 Lamp Cord Coleman 946036618 Speaker Cable Romex SIMpull 8/2NM-WGX125 Type NM-B Building Wire
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 V maximum. PVC insulation and UL62, UL1581 listed. Spool. Two bare copper conductors laid flat with integral PVC insulation and jacket. Clear jacket construction has one bare copper and one tinned copper conductor. Temperature rated from -20 to 60 deg C, operating voltage 300 V maximum. 18/2 stranded, flat, boxed. UL Standard 13 & 444, CSA C22.2 No. 214, NEC Article 725 & 800. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire Coleman 553076607 Type CL-2 Solid Thermostat Cable Barostat 553036607 Solid Type CL-2 Thermostat Cable
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 deg C. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 V. PVC insulation UL13 for power limited circuit cable for other than plenum, riser or tray uses and UL1581 approved. 500 ft reel, 18 AWG conductor soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 deg C. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 V. PVC insulation UL13 for power limited circuit cable for other than plenum, riser or tray uses and UL1581 approved.
Romex SIMpull 12/3NM-WGX250 Type NM-B Building Wire Romex SIMpull 12/3UF-WGX250 Type UF-B Building Wire Duraclad 55274901 Type MC Armored Cable
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.
Romex SIMpull 28827472 Type NM-B Building Wire Romex SIMpull 10/2NM-WGX250 Type NM-B Building Wire Romex SIMpull 10/2UF-W/GX250 Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. Romex Building Wire, NM-B, 10 AWG Wire, 250 ft Length, 2 Conductors, Strands per Conductor: 1, Copper Conductor, PVC Conductor Insulation, Solid, Nylon Sheath, Orange Sheath, 600 V, 30 A, 90 deg C Operating Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Southwire 4STRDX200BARE Stranded Electrical Wire Southwire 4SOLX200BARE Solid Electrical Wire Southwire 6STRDX315BARE Stranded Electrical Wire
Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications. Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook up, jumpers and grounds in electrical construction. Soft drawn copper is unilay construction. Equipment and circuit grounding. Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems.
Southwire 8BLK-STRX500 Stranded Single Building Wire Southwire 8WHT-STRX500 Stranded Single Building Wire Southwire 8RED-STRX500 Stranded Single Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 20492512 Stranded Single Building Wire Southwire 8SOLX500BARE Solid Electrical Wire Southwire 6SOLX315BARE Solid Electrical Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Southwire Bare Wire, 8 AWG Wire, Copper Conductor, Solid, 500 ft Length, 95 A, 75 deg C Operating Southwire Bare Electrical Wire, 6 AWG Wire, Copper Conductor, Solid, 315 ft Length, 125 A, 75 deg C Operating
Barogation 547050408 Sprinkler Cable Romex SIMpull 8/3NM-WGX125 Type NM-B Building Wire Romex SIMpull 6/2NM-WGX125 Type NM-B Building Wire
Southwire Sprinkler Wire, 18 AWG Wire, 250 ft Length, 5 Conductors, Polyethylene Conductor Insulation, Stranded, 0.246 in Sheath Diameter, 24 V, -20 to 75 deg C Operating Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Armorlite 68583401 Type MC Armored Cable Southwire 65676902 Electrical Wire Romex SIMpull 14/2NM-WGX1000 Type NM-B Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed. ETL Listed type CL2 power limited circuit cable is a general-purpose 8 conductor low voltage control cable. Construction provides solid uncoated copper conductors insulated with polyvinyl chloride (PVC) insulation twisted together without filler and covered with an ETL listed sunlight-resistant PVC jacket. Conductor colors are red, white, green, blue, yellow, brown, orange and black. Used for air conditioning controls, heat pumps, heating controls, thermostats and bell and alarm systems. For use in accordance with the NEC Article 725. Rated 60 deg C continuous in air. Solid 18/8 type CL2. Meets UL 1581 vertical flame tray test. 15 mil jacket thickness, approximately 202 mil overall cable diameter. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Romex SIMpull 63947672 Type NM-B Building Wire Romex SIMpull 28828272 Type NM-B Building Wire Quantum TPE 16/3 SJEOOW 250' SJEOOW Electrical Cord
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. Provides premium oil resistance, water resistance and flexibility. Use in wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites. Approved for outdoor use. May be completely immersed in water. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential. Extra flexible copper conductors. Rated at -60 to 105 deg. 13 A - 300 V - 250 ft coil. Meets all applicable requirements of: ASTM, UL 62 and CSA Standard 22.2 No 49. OSHA acceptable. C-UL, UL and MSHA listed. All sizes meet CSA FT-2.
Romex SIMpull 10/3NM-WGX250 Type NM-B Building Wire Coleman 2333850408 SJEW Electrical Cable Coleman 232860408 SJEW Electrical Cable
Southwire? Romex? brand SIMpull? NM-B (non-metallic sheathed) cable may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the national electrical code. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not wet or damp locations. Voltage rating for NM-B cable is 600 V. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. For hard usage applications in accordance with NEC. Flexible and tough jacket. Temperature range of -50 to 105 deg C. Used for portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90 conductor. TPE insulation. UL62, UL1581 and CSA-C22.2 No 49 approved.
Romex SIMpull 63946872 Type NM-B Building Wire Romex SIMpull 10/3UF-WGX250 Type UF-B Building Wire Barogation 547070408 Solid Sprinkler Cable
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Underground sprinkler system wire. 18/7 solid, 30 V RMS max. Used for sprinkler control systems. Soft annealed solid copper per ASTM B3-90. Polyethylene insulation and jacket. 18 AWG bare copper. Cable consists of 7 bare copper insulated conductors with an overall outer jacket diameter of 0.268 in. UL listed.
Romex SIMpull 8/2UF-W/GX125 Type UF-B Building Wire Coleman 233860408 SJEW Electrical Cord Romex SIMpull 12/2NM-WGX1000 Type NM-B Building Wire
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Hard service thermoplastic insulated conductors and overall thermoplastic jacket. All elastomer construction. Conductor is soft annealed stranded copper per ASTM B3-90. Temperature range from -50 to +105 deg C. For hard usage applications in accordance with NEC and for use with portable tools and lamps, pumps and portable farm equipment. Weather-resistant. 300 V - 250 ft spool. UL 62, UL1581, CSA-C22.2 No 49. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Romex SIMpull 6/3NM-WGX125 Type NM-B Building Wire Romex SIMpull 63950072 Type NM-B Building Wire Romex SIMpull 63949272 Type NM Building Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code.
Southwire 6BK-STRX500 Stranded Single Building Wire Southwire 6WHT-STRX500 Stranded Single Building Wire Southwire 6RED-STRX500 Stranded Single Building Wire
Southwire Building Wire, THHN, Wire Size: 6 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: Black, Sheath Diameter: 1/4 in, 600 V, 65 A, Operating Temperature: 194 deg F Southwire Building Wire, THHN, Wire Size: 6 AWG, 500 ft L, Number of Conductors: 1, Strands per Conductor: 19, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: Nylon, Sheath Color: White, Sheath Diameter: 1/4 in, 600 V, 65 A, Operating Temperature: 194 deg F Southwire Building Wire, THHN, Wire Size: 6 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: PVC, Sheath Color: Red, 600 VAC, 55 A, Operating Temperature: 90 deg C
Southwire 6GRN-STRX500 Stranded Single Building Wire Coleman 232870408 SJEW Electrical Cord Coleman 203076603 SJTW Electrical Cable
Southwire Building Wire, THHN, Wire Size: 6 AWG, 500 ft L, Number of Conductors: 1, Conductor Material: Copper, Conductor Insulation: PVC, Stranded/Solid: Stranded, Sheath Material: PVC, Sheath Color: Green, 600 VAC, 55 A, Operating Temperature: 90 deg C For hard usage applications in accordance with NEC. Flexible and tough jacket. Temperature range of -50 to 105 deg C. Used for portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90 conductor. TPE insulation. UL62, UL1581 and CSA-C22.2 No 49 approved. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather-resistant PVC jacket. Orange, 250 ft spool. UL62, UL1581 and CSA approved.
Romex SIMpull 63948472 Type NM-B Building Wire Romex SIMpull 12/2UF-WGX500 Type UF-B Building Wire Coleman 233896608 SJEW Electrical Cable
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. CCI Electrical Cable, SJEW, 10 AWG Wire, 100 ft Length, 3 Conductors, Copper Conductor, TPE Conductor Insulation, Stranded, TPE Sheath, Black Sheath, 300 V, 30 A
Romex SIMpull 12/2NMW/GX500FT Type NM-B Building Wire Coleman 233870408 SJEW Electrical Cable Romex SIMpull 6/2UF-W/GX125 Type UF-B Building Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved, 250 ft spool. Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.
Coleman 233270408 SJEOOW Flexible Power Cord Coleman 203086603 SJTW Electrical Cord Southwire 4BK-STRX500 Stranded Single Building Wire
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather-resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250 ft spool. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather-resistant PVC jacket. Orange, 250 ft spool. UL62, UL1581 and CSA approved. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire 4WH-STRX500 Stranded Single Building Wire Southwire SEU Service Entrance Cable Wire Romex SIMpull 12/2UF-W/GX1000 Type UF-B Building Wire
Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Southwire Ground Wire, 600 V, 20 A, Copper Conductor, 2 Conductors, Strands per Conductor: 1, Nylon Sheath, Gray Sheath, 12 AWG Wire, 1000 ft Length
Coleman 234270408 SJEOW Electrical Cable Coleman 223280408 SEOOW Electrical Wire Coleman 233880408 SJEW Electrical Cable
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather-resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250 ft spool. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather-resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250 ft spool. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved, 250 ft spool.
Romex SIMpull 8/2NM/WG 500 FT Type NM-B Building Wire Southwire 3BK-STRX500 Stranded Single Building Wire Southwire 12/2X500 W/G Quartz Single Ended Electrical Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Pump cable, type THW, thermoplastic (PVC) insulated, 600 V. All wire insulated.
Southwire SEU Service Entrance Cable Coleman 233280408 SJEOOW Electrical Cord Southwire Stephens Triplex Building Wire
Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 deg C in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944 and NEC requirements. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather-resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250 ft spool. Consists of two cross-linked polyethylene insulated phase conductors triplexed with a yellow-striped, cross-linked polyethylene insulated neutral. High quality heat and moisture-resistant cross-linked polyethylene is rated 75 deg C for wet and 90 deg C for dry locations. 120 A maximum in duct or 165 A in direct earth burial applications with a maximum conductor temperature of 90 deg C, 600 V. 2 - 2 - 4 URD x 500 ft spool. UL listed.
Romex SIMpull 12/3NM-WGX1000FT Type NM-B Building Wire Southwire SEU Service Entrance Cable Wire Southwire 2-2-4-6X500AL USE In-Use Service Entrance Cable Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. 3 conductors, 1000 ft spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 deg C for dry locations or 75 deg C for wet locations, 600 V. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight- and moisture-resistant, flame retardant jacket. UL listed. Amp capacities listed are at 30 deg C/85 deg F. Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact Stranded 8000 Series aluminum alloy. 600 V. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 deg C. Quadruplex cable conductor construction. UL listed.
Southwire SEU Service Entrance Cable Southwire 2BK-STRX500 Linear Building Wire Romex SIMpull 10/2NM-WGX1000 Type NM-B Building Wire
Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 deg C in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944 and NEC requirements. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Southwire SER Service Entrance Cable Southwire 12/3X500 W/G Electrical Wire Romex SIMpull 6/2NM-WGX500 Type NM-B Building Wire
Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 deg C. 600 V maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements. Pump cable, type THW, thermoplastic (PVC) insulated, 600 V. All wire insulated. Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.
Romex SIMpull 8/3NM-W/GX500 Type NM-B Building Wire Coleman 224280408 SEOOW Electrical Wire Coleman 22329M408 SJEOOW Electrical Cable
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather-resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250 ft spool. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather-resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250 ft spool.
Coleman 223290408 SEOOW Electrical Wire Southwire Sweetbriar Triplex Building Wire Romex SIMpull 10/3NM-WGX1000FT Type NM-B Building Wire
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather-resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 deg Celsius to 105 deg C. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather-resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250 ft spool. Compact stranded 8000 Series aluminum alloy. Cross-linked polyethylene (XLPE) insulation. Multiplexed cable conductors with a left hand lay in a Triplex (3 conductor) assembly. Underground distribution from a supply source to the service entrance equipment of a building. Maximum operating temperature of 90 deg C in dry and wet locations. 315 A maximum in direct burial application or 240 A in ducts. 4/0 - 4/0 - 2/0 x 500 ft spool, 600 V. Black color. UL listed Type USE-2. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 deg C (with ampacity limited to that for 60 deg C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 V. 3 conductors, 1000 ft spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544 and requirements of the National Electrical Code.
Southwire 55039401 Power Supply Cord Romex SIMpull 10/2UF-W/GX1000 Type UF-B Building Wire Southwire 1/0BK-STRX500 Stranded Single Building Wire
Southwire Power Cord, Portable, 10 AWG Wire, 250 ft Length, 4 Conductors, Strands per Conductor: 104, 104/30 Strand, Copper Conductor, TPE Conductor Insulation, Stranded, TPE Sheath, Black Sheath, SEOOW Shielding, 600 V, 25 A, -50 to 105 deg C Operating Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Romex SIMpull 6/3NM-W/GX500 Type NM-B Building Wire Quantum TPE 55044903 SEOOW Power Cord Southwire 1BLK-STRX500 Stranded Single Building Wire
Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed. Wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites. 8 ga, 3 conductor stranded with insulated ground. Rated -50 to 105 deg C. 40 A, 600 V. RoHS compliant. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Romex SIMpull 6/2UF-W/GX500 Type UF-B Building Wire Southwire MBL Service Entrance Cable Wire Southwire 10/3X500 W/G Twisted Electrical Wire
Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed. Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact Stranded 8000 Series aluminum alloy. 600 V. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 deg C. Quadruplex cable conductor construction. UL listed. Pump cable, type THW, thermoplastic (PVC) insulated, 600 V. All wire insulated.
Southwire SEU Service Entrance Cable Southwire Monmouth Triplex Building Wire Southwire 2/OBK-STRX500 3-Way Torchiere Building Wire
Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 deg C in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944 and NEC requirements. Consists of two cross-linked polyethylene insulated phase conductors triplexed with a yellow-striped, cross-linked polyethylene insulated neutral. High quality heat and moisture-resistant cross-linked polyethylene is rated 75 deg C for wet and 90 deg C for dry locations. 240 A maximum in duct or 315 A in direct earth burial applications with a maximum conductor temperature of 90 deg C, 600 V. 4/0 - 4/0 - 4/0 URD x 500' spool. UL listed. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant.
Southwire SEU Service Entrance Cable Wire Southwire 3/0BK-STRX500 Stranded Single Building Wire Southwire SER Service Entrance Cable
Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 deg C for dry locations or 75 deg C for wet locations, 600 V. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight- and moisture-resistant, flame retardant jacket. UL listed. Amp capacities listed are at 30 deg C/85 deg F. Southwire? SIMpull THHN? copper conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the National Electrical Code. Voltage for all applications is 600 V. SIMpull THHN? copper conductors are designed to be installed without application of a pulling lubricant. Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 deg C. 600 V maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements.
   
 
1